Power and voltage range 
			200-240 V ….. 0.25 kW – 45 kW
			380-480 V ….. 0.37 kW – 1000kW
			525-600 V ….. 0.75 kW – 90 kW
			525-690 V ….. 11 kW – 1.4 MW 
			Three phase
			3*200-240V… 0,25-45kW
			3*380-480V… 0,37-1000kW 
			3*525-600V… 0,75-90kW 
			3*525-690V… 11-1.4 MW 
			Single phase 
			1*200-240V 1.1-22kW 
			1*380-480V 7.5-37kW
			Enclosures – IP20/chassis, IP21/NEMA 1, IP55/NEMA 12 and IP66/NEMA 4X
			Dedicated water features Auto tuning of the PI controllers – With auto tuning of the PI controllers, the drive monitors how the system reacts on corrections made by the drive – and learns from it, so that precise and stable operation is achieved quickly. 
			Automatic Energy Optimization – The standard feature AEO provides optimized motor magnetization at all speeds and loads. This increases energy efficiency by 5-15% for partial loads. 
			Energy monitoring – The VLT AQUA Drive provides a complete range of energy consumption information, which helps identify low-efficiency components in the system. 
			PM motor support – Support for any non salient permanent magnet motor up to 22 kW for better system efficiency.
			Pipe Fill Mode – Enables controlled (closed loop) filling of pipes. Prevents water hammering, bursting water pipes or blowing off sprinkler heads.
			End of Pump Curve detects breaks and leakage – The feature detects breaks and leakage. End of curve triggers an alarm, shuts off the pump or performs another userdefined action. 
			Dry Pump Protection lowers maintenance costs – The VLT® AQUA Drive constantly evaluates the condition of the pump, based on internal frequency/power measurements. 
			Deragging – Can be used as a proactive or reactive feature of the AQUA Drive for wastewater applications to prevent clogging of pumps. Deragging helps to avoid downtime and reduces maintenance cost.
			Cascade controller solutions – The built-in standard cascade controller controls up to three pumps with a fixed lead pump. The optional Extended and Advanced Cascade Controller makes it possible to extend the number of pumps and ensure smooth staging/de-staging, also in mixed pump and variable speed pump applications.
			Motor Alternation – This built-in logic controls alternation between two pumps in duty/stand-by applications. Motion of the stand-by pump prevents the pump from sticking. An internal timer assures equal usage of the pumps.
			Flow compensation – The flow compensation feature reduces the pressure set point according to the flow, which saves energy. 
			Initial/Final Ramp – The initial ramp provides fast acceleration of pumps to minimum speed, from where the normal ramp takes over. This prevents damage on thrust and bearings.
			Check Valve Ramp – The Check Valve Ramp of the VLT AQUA Drive prevents water hammering as check valves close smoothly when the pump stops. 
			Quick Menu – The user-friendly Quick Menu and its submenus of the VLT AQUA Drive, saves time during drive configuration. The submenu “Water and Pumps” provides direct access to application specific features.
			Safety – The VLT® AQUA Drive can optionally be delivered with the safe torque off (safe stop) functionality suitable for category 3, performance level d according to EN 13849-1 and SIL 2 according to IEC 62061/IEC 61508. This feature prevents the drive from starting unintended. 
			Accessories – A wide selection of accessories is available for the VLT® AQUA Drive to suit your needs. For further details see the Operation Instructions. 
			Options – Options for bus communication, user programs, etc., are delivered ready for plug and play. 
			Display options – Local Control Panel LCP (graphical and numerical), Cable for LCP, 3 m [9,8 ft.], Remote-mounting kit for Local Control Panel (LCP), Blind cover 
			Fieldbus options – VLT PROFIBUS DP/V1 MCA 101, VLT DeviceNet MCA 104, VLT PROFINET MCA 120, VLT EtherNet IP MCA 121, VLT Modbus TCP MCA 122
			I/O options – VLT Extended I/O MCB 101, VLT Relay Card MCB 105), VLT Extended Cascade Controller MCO 101, VLT Advanced Cascade Controller MCO 102, VLT Analog I/O MCB 109, VLT PTC Thermistor Card MCB 112, VLT Sensor Input MCB 114
			Filters – VLT Advanced Harmonic Filter AHF 005/010, VLT Sine-wave Filter MCC 101, VLT dU/dt Filter MCC 102, VLT Common Mode Filter MCC 105 
			PC software tools – VLT Motion Control Tool MCT 10 for commissioning and servicing, VLT Motion Control Tool MCT 31 for calculating harmonic distortion 
			Other accessories – VLT 24V external supply MCB 107, IP21/NEMA1 Kit, Kit for panel through mount, USB connection cable to PC
			Order Codes – For basic Drives 380-480 VAC
			
				
					
						| Order Code (IP20) | 
						Order Code (IP55) | 
						KW | 
						Amps | 
						Filter | 
					
					
						| 131B8872 | 
						131B8875 | 
						0.37 | 
						1.3  | 
						H1 | 
					
					
						| 131B8880 | 
						131B8883 | 
						0.55 | 
						1.8 | 
						H1 | 
					
					
						| 131B8888 | 
						131B8891 | 
						0.75  | 
						2.4  | 
						H1 | 
					
					
						| 131B8896  | 
						131B8900 | 
						1.1  | 
						3 | 
						H1 | 
					
					
						| 131B8290  | 
						131F0652  | 
						1.5  | 
						4.1 | 
						H1 | 
					
					
						| 131B8906  | 
						131B8909  | 
						2.2  | 
						5.6  | 
						H1 | 
					
					
						| 131B8914  | 
						131B8917  | 
						3.0 | 
						7.2 | 
						H1 | 
					
					
						| 131B8932  | 
						131B9332  | 
						4.0  | 
						10  | 
						H1 | 
					
					
						| 131B8942  | 
						131B8947  | 
						5.5  | 
						13  | 
						H1 | 
					
					
						| 131B8289  | 
						131B8972 | 
						7.5  | 
						16  | 
						H1 | 
					
					
						| 131F6639 | 
						131B9001  | 
						11 | 
						24  | 
						H1 | 
					
					
						| 131F6644  | 
						131B9008  | 
						15 | 
						32  | 
						H1 | 
					
					
						| 131F6648  | 
						131B9016  | 
						18.5  | 
						37.5  | 
						H1 | 
					
					
						| 131F6768  | 
						131B9025 | 
						22 | 
						44  | 
						H1 |